Estimate slab resonances
Choose a slab, a flaw, and a steel ball. First-order plate and contact relations give the mode frequencies, and each is compared with the 24 kHz Nyquist limit of a 48 kHz recorder and with a nominal impact bandwidth.
Calculator
Sampling compares each frequency with the 24 kHz Nyquist limit of a 48 kHz recorder. Impact bandwidth compares it with the nominal 1.25 / tc estimate for the chosen ball.
| Quantity | Estimate | Regime | Sampling | Impact bandwidth |
|---|---|---|---|---|
| Full-thickness mode fpβ·cp / (2H) | 9.60 kHz | Regimes I, II | Below 24 kHz | Within≤ nominal 24.2 kHz |
| Delamination thickness branch fdcp / (2d), ideal round trip | 40.0 kHzwith β: 38.4 kHz | Between II and III | Above 24 kHzaliases at 48 kHz sampling | Aboveneeds D ≤ 7.2 mm, not in the 12–19 mm set |
| Cover-plate flexure fflexclamped circular plate, r = a/2 | 4.04 kHzideal clamped edgea/d = 6.0: thick cover, likely high | Regimes I, II | Below 24 kHz | Within≤ nominal 24.2 kHz |
| Nominal contact time tc≈ 0.0043·D, 4.3 µs per mm | 51.6 µs | — | — | — |
| Estimated impact bandwidth fmax≈ 1.25 / tc | 24.2 kHz | Nominal estimate reaches the 24 kHz sampling limit. The impact spectrum rolls off continuously, so read this value as a marker rather than a sharp cutoff. | ||
Frequency map
The full-thickness mode (fp = 9.60 kHz) and cover-plate flexure (fflex ≈ 4.04 kHz, likely high for a thick cover at a/d = 6.0) fall below the 24 kHz sampling limit and within the nominal 24.2 kHz bandwidth of the 12 mm ball. The thickness branch (fd = 40.0 kHz, or 38.4 kHz with β) lies above both limits, so a 48 kHz recorder would alias it and the same bandwidth estimate would need a ball of about 7.2 mm or smaller, outside the planned 12–19 mm set. Below the sampling limit, the candidate indicators of this flaw are the flexural peak and a reduced full-thickness peak.
A predicted peak can be weak, masked, or absent. Contact, receiver coupling, analog filtering, and noise determine whether it can be measured, and overlap with a regime band does not identify the mechanism.
Cross-section
The relations assume an ideal plate and an ideally clamped circular cover. They leave out reinforcement, finite plan dimensions, partial contact across the flaw, and dispersion.
Governing relations
In relations (1)–(5), lengths are in meters, velocity in m/s, and time in seconds.
Thickness resonance of a plate of thickness H, with β ≈ 0.96 for plate geometry and cp measured on the member. ASTM C1383 applies this relation to plates whose lateral dimensions are at least six times the thickness (≥ 6H), and it does not cover plates with overlays.
Ideal normal round-trip estimate to a reflector at depth d that is extensive compared with d. Applying it to a delamination is a modeling choice. The β-adjusted value shown by the explorer is a sensitivity comparison.
Fundamental flexural mode of the cover, modeled as an isotropic circular plate of thickness d and radius r = a/2 with an ideally clamped edge: λ2 ≈ 10.216 and ν = 0.2, with E/ρ inferred from cp. Ideal clamping gives a stiff-edge reference for the same plate; restraint, finite cover geometry, reinforcement, and contact across the flaw can change the measured mode. Thin-plate theory overstates the frequency when the cover is thick for its span, so the explorer flags a/d below 10 in the result row. The plan width a = 300 mm is an illustrative explorer value.
Nominal contact time in seconds for a steel sphere of diameter D in meters on concrete, equivalent to 4.3 µs per mm. Hertzian contact time also depends on impact velocity and on the elastic properties of both bodies, so the coefficient is an approximation for assumed impact conditions.
Approximate upper frequency of useful excitation. The impact spectrum rolls off continuously, so this is a nominal marker that depends on the roll-off criterion, not a cutoff. It gives 24.2 kHz for a 12 mm ball and 15.3 kHz for a 19 mm ball, the two ends of the pre-registered impactor set; at 19 mm the estimate lies below the 24 kHz sampling limit.
Regime boundaries
At a nominal cp = 4,000 m/s, the 25–75 mm delaminations of the pre-registered slab matrix have ideal thickness-branch frequencies of 26.7–80 kHz, above the 24 kHz Nyquist limit.
The margin depends on the mix. A lower-velocity concrete, such as the high-w/c mix of SLAB-04, can bring the 75 mm case close to the limit: at 3,600 m/s it falls at 24 kHz. Below the limit, the model’s candidate indicators are cover-plate flexure and a reduced full-thickness peak.
| Regime | Band | Capture |
|---|---|---|
| I · Flexural sounding | 0.3–16 kHz | Below the 24 kHz Nyquist limit of a 48 kHz audio converter |
| II · Impact-echo | 2–20 kHz | |
| III · Ultrasonic and coda wave | 50–500+ kHz | Above that limit; dedicated ultrasonic transducers or laser vibrometry |
Sources for relations (1)–(5)
Sansalone, M. J., and Streett, W. B. Impact-Echo: Nondestructive Evaluation of Concrete and Masonry. Bullbrier Press, Ithaca, NY, 1997.
ASTM C1383. Standard Test Method for Measuring the P-Wave Speed and the Thickness of Concrete Plates Using the Impact-Echo Method. ASTM International.
Leissa, A. W. Vibration of Plates. NASA SP-160, 1969.