TremOR Operation Research Group 1 / 6

Structural stress-wave research

A paired measurement on the same specimen

Our undergraduate-led team at Purdue University in Indianapolis studies flexural sounding (0.3–16 kHz) and impact-echo (2–20 kHz) with a 48 kHz commercial off-the-shelf (COTS) stack, and seeks university partners for 50–500+ kHz ultrasonic and coda measurements on characterized concrete or masonry specimens.

Regime I Flexural sounding 0.3–16 kHz Cover-plate bending
Regime II Impact-echo 2–20 kHz 24 kHz COTS Nyquist ceiling
Regime III Ultrasonic & coda 50–500+ kHz Partner laboratory instruments

Screening and triage tool for engineer-supervised structural inspection; not a standalone structural safety determination.

Purdue University in Indianapolis · November 2026

TremOR Operation Research Group 2 / 6

Measurement physics

What a 48 kHz recorder can capture

Logarithmic frequency bands. Flexural sounding spans 0.3 to 16 kHz, impact-echo spans 2 to 20 kHz, and ultrasonic or coda methods span 50 to 500+ kHz with an open upper continuation. The 48 kHz COTS Nyquist ceiling sits at 24 kHz. I · Flexural sounding II · Impact-echo III · Ultrasonic & coda 0.3 2 20 200 500+ kHz Frequency (kHz, logarithmic scale) 0.3–16 kHz 2–20 kHz 50–500+ kHz 24 kHz Nyquist (48 kHz ADC)

24 kHz COTS Nyquist ceiling (dashed)

I · Flexural sounding 0.3–16 kHz
II · Impact-echo 2–20 kHz
III · Ultrasonic & coda 50–500+ kHz
0.3 2 20 200 500+ kHz

0.3–20 kHz · Within 48 kHz COTS capturePlate bending over shallow debonding and P-wave thickness reflections both fall below the 24 kHz Nyquist ceiling.

50–500+ kHz · Partner instrumentationUltrasonic transducers and scanning laser Doppler vibrometry resolve diffuse scattering and early micro-cracking above the audio-rate limit.

TremOR Operation Research Group 3 / 6

Paper 1 · Corpus-leakage audit

Three corpora contain 1,796 cross-corpus copies

Proportional breakdown of 5,370 parsed records across three impact-echo corpora: 3,543 globally unique waveforms (66.0%), 1,796 cross-corpus copies (33.4%), and 31 within-corpus duplicates (0.6%). 5,370 parsed records (FHWA Bare Decks 2,015 · IE2020 1,828 · Overlay IE2020 1,527) 3,543 globally unique (66.0%) 1,796 cross-corpus (33.4%) Globally unique · 3,543 (66.0%) Cross-corpus copies · 1,796 (33.4%) Within-corpus duplicates · 31 (0.6%) 5,370 parsed − 1,796 cross-corpus copies − 31 within-corpus duplicates = 3,543 globally unique waveforms

5,370 parsed records across FHWA Bare Decks (2,015), IE2020 (1,828), and Overlay IE2020 (1,527)

  • Globally unique waveforms 3,543 (66.0%)
  • Cross-corpus copies 1,796 (33.4%)
  • Within-corpus duplicates 31 (0.6%)

5,370 − 1,796 − 31 = 3,543 globally unique

0 of 23 nested outer folds supportedNo outer fold cleared support floors under group-disjoint evaluation (0 leakage violations); native leave-one-lab-out balanced accuracy ranged from 0.5642 to 0.6636.

0.6765 corpus-identity accuracyThe source-identity probe exceeded the 0.5159 majority-class rate in both native (0.6765) and common-band (0.6689) views.

TremOR Operation Research Group 4 / 6

Benchmarks and pilots

Two field-data baselines and one composite-plate pilot

PhysNDE-Bench v1

473 → 391

Harvested entries audited to 391 eligible, non-duplicate field records; 82 entries were quarantined, including duplicates and simulated data labeled as field data.

Bare Decks (8 slabs), leave-one-slab-out (LOSO) mean ROC AUC 0.5097.

Reinforced-concrete structures (zenodo-22981791, 2 structures), leave-one-structure-out (LSSO) mean ROC AUC 0.6727.

ElastoWave-NO

0.8761 vs 0.8727

Finite-element calibration versus training from scratch on one laboratory glass-fiber-reinforced polymer (GFRP) chirp wavefield (175 mm ring, k = 8). Descriptive AUC delta is +0.0034 on a single composite plate.

doi:10.5281/zenodo.15640329

CausalSHM-Env · Under temporal forward-chaining, the FLOOD-SHAB structural monitoring record showed air temperature vs. first-mode frequency correlation r = −0.563, and the Vänersborg fracture dataset spans 8 healthy and 6 damaged events.

TremOR Operation Research Group 5 / 6

Paper 2 · Planned field protocol

Planned comparison with the Olson NDE 360

COTS bill of materials (≤ $300 cap)

USB-C 24-bit / 48 kHz ADC $89.00
Contact piezo accelerometer + preamp $115.00
Steel ball-peen impactor set (12–19 mm) $28.00
Shielded cables & couplant gel $36.00
Total $268.00

Six-slab matrix (150 mm co-located grid)

Pair COTS and Olson NDE 360 measurements at matching grid coordinates across six planned slabs:

Slab class Condition / delamination depth
200 mm normal-weight Sound control, 25 mm, or 50 mm
250 mm high-w/c Sound control or 75 mm
200 mm lightweight 35 mm delamination

Pre-registered Protocol thresholds · Contact-slab AUROC ≥ 0.80; lightweight-mode fallback triggers at a 0.10 accuracy gap and 0.20 abstention rate under 70 dBA ambient noise; target ≥ 20% total time reduction and ≤ 10% Professional Engineer (PE) review delta. Slab casting and field timing await institutional clearance.

TremOR Operation Research Group 6 / 6

Data custody and collaboration

Specimens and recordings sought

T0 · Open Permissive
CC BY 4.0, CC0, MIT, Apache-2.0. Open benchmarks, cross-lab leakage baselines, and reproducible public release.
T1 · Academic / Non-Commercial
Segregated in non-commercial evaluation views only; strictly excluded from any commercial model weights.
T2 · Partner Custody
Bilateral university or institutional data-exchange agreement. Joint waveform validation with shared authorship and explicit custody terms.

What to send · Specimen geometry and concrete or masonry mix, documented delamination or crack state, excitation source and transducer bandwidth (50–500+ kHz), sampling rate, sensor positions, and preferred custody tier.