TremOR Operation Research Group

Ultrasonic measurements for a concrete slab comparison

Our undergraduate-led team at Purdue University in Indianapolis studies flexural sounding (0.3–16 kHz) and impact-echo (2–20 kHz) with a 48 kHz commercial off-the-shelf (COTS) stack. We seek university partners to record 50–500+ kHz ultrasonic or coda wavefields on characterized concrete or masonry specimens so both frequency ranges can be compared on the same structure.

Screening and triage tool for engineer-supervised structural inspection; not a standalone structural safety determination.

Frequency bands and instrumentation

Regime Band Instrumentation and physical response
I · Flexural sounding 0.3–16 kHz Manual hammer strike with microphone or contact piezo captures local cover-plate bending over shallow debonding.
II · Impact-echo 2–20 kHz Contact piezo accelerometer captures P-wave thickness reflections; a 48 kHz sampling rate sets a 24 kHz Nyquist ceiling.
III · Ultrasonic & coda 50–500+ kHz Dedicated ultrasonic transducers or scanning laser Doppler vibrometry (SLDV) resolve diffuse scattering and early micro-cracking above the 24 kHz audio limit.

Completed audits and pilots

Paper 1 · Corpus-leakage audit

Across three public impact-echo corpora, 5,370 parsed records contain 3,543 globally unique waveforms (1,796 cross-corpus copies and 31 within-corpus duplicates). Zero of 23 nested outer folds cleared support floors; corpus-identity accuracy reached 0.6765 native and 0.6689 common-band against a 0.5159 majority-class rate.

PhysNDE-Bench v1

Of 473 harvested entries, 391 are eligible, non-duplicate field records and 82 are quarantined. Held-out mean ROC AUC was 0.5097 on Bare Decks (8 slabs, leave-one-slab-out) and 0.6727 on reinforced-concrete structures (zenodo-22981791, 2 structures, leave-one-structure-out).

ElastoWave-NO

On one laboratory glass-fiber-reinforced polymer (GFRP) chirp wavefield (175 mm ring, k = 8), finite-element calibration yielded AUC 0.8761 versus 0.8727 from scratch (descriptive delta +0.0034; single composite plate). 10.5281/zenodo.15640329

CausalSHM-Env

Under temporal forward-chaining, the FLOOD-SHAB structural monitoring record showed air temperature vs. first-mode frequency correlation r = −0.563; the Vänersborg real-fracture dataset spans 8 healthy and 6 damaged events.

Paper 2 · Planned six-slab comparison Pre-registered

A $268.00 COTS 24-bit / 48 kHz stack will be paired with an Olson NDE 360 on a 150 mm co-located grid across six concrete slabs (200–250 mm thick; sound controls and 25–75 mm delaminations). Pre-registered target: contact-slab AUROC ≥ 0.80. Slab casting and field timing await institutional clearance.

Data-sharing tiers and partner inquiries

T0 · Open Permissive
CC BY 4.0, CC0, MIT, Apache-2.0. Open benchmarks, cross-lab leakage baselines, and reproducible public release.
T1 · Academic / Non-Commercial
Segregated in non-commercial evaluation views only; strictly excluded from any commercial model weights.
T2 · Partner Custody
Bilateral university or institutional data-exchange agreement. Joint waveform validation with shared authorship and explicit custody terms.